hair removal
hair removal facts: click for consumer recommendations
  
  Home  Methods  IPL (intense pulsed light)   
   
NAVIGATION




Hair Removal Home
Hair Removal Methods
Hair Removal Directory
Hair Removal Search

Hair Removal "Permanent" *
Hair Removal Electrolysis *
Hair Removal Home electro *
Hair Removal Laser *
Hair Removal Flashlamp/IPL *
Hair Removal Combinations *
space * seeHair Removal note

Hair Removal Hair inhibitors
Hair Removal Home laser
Hair Removal Rx oral meds
Hair Removal Vaniqa

Hair Removal Temporary
Hair Removal Shaving
Hair Removal Depilatories
Hair Removal Friction
Hair Removal Tweezing
Hair Removal Waxing
Hair Removal Sugaring
Hair Removal Threading
Hair Removal Rotary epilators

Hair Removal Doubtful
Hair Removal Electric tweezer
Hair Removal Transdermal
Hair Removal Transcutaneous
Hair Removal Photoepilators
Hair Removal Microwaves
Hair Removal Dietary products
Hair Removal Herbal inhibitors

Hair Removal Recommended
Hair Removal Epilators
Hair Removal Electric razors
Hair Removal Home electrolysis
Hair Removal Home laser/IPL
Hair Removal Hot wax kits
Hair Removal Tweezers
Hair Removal Aftercare
Hair Removal Books

Hair Removal Other topics
Hair Removal  How to choose
Hair Removal  Tips
Hair Removal  Clinical data
Hair Removal  Manufacturers
Hair Removal  Regulation
Hair Removal  Info sources
Hair Removal  Scams
Hair Removal  Ripped off?

Hair Removal  FAQ
Hair Removal  Glossary
Hair Removal  Site info
Hair Removal  Feedback

Flashlamps/Intense Pulsed Light (IPL)

Background

The light-based hair removal method called > flashlamp is also called IPL (intense pulsed light), ILS (intense light source), full spectrum, non-coherent, and broadband light. The primary differences between flashlamps and lasers used in hair removal are:

Kind of light

As mentioned earlier, flash lamps do not use one wavelength of light the way a laser does. Flashlamps emit every wavelength of light in the visible spectrum, and a little into the band of infrared radiation (up to about 1200 nm). Practitioners select a cutoff filter to block out lower wavelengths.

Size and shape of the spot (beam)

Most flashlamps emit a beam that covers more area than a laser. Most flashlamps also have a rectangular spot, rather than the round type usually standard on lasers.

History

Xenon is commonly used as a light source because of the brilliant, full spectrum illumination it provides when exposed to energy. Like laser, it can be designed to be extremely powerful and has industrial applications like paint stripping. It is also used for items such as the flashes in photographic equipment and in surgical lighting equipment.

The xenon flashlamp, first developed as an energy source for laser beams, was soon being used therapeutically with direct applications of its energy. As with lasers, flash lamps began to be used for medical purposes in the 1960's. The latter half of the 1960's saw published data on treating eye and skin disorders. [1, 2]

Early attempts in the 1970's to use xenon light energy delivered via fiberoptic filament have not been demonstrated to be permanent. Although these devices (see photoepilators) are still in use, they should not be confused with the devices that became available 25 years later.

By the mid-1990's, researchers were exploring the use of flashlamps for treating vascular lesions. In the year the first flashlamp was cleared by FDA for use in treating vascular lesions, [3] one study noted hair loss as a side effect of treatment. [4] Other papers indicated promising results for some in the treatment of leg veins, [5, 6] prompting one manufacturer to apply for and receive FDA clearance for hair removal in 1997. [7] In 2000, FDA began allowing some brands to claim permanent hair reduction in most skin types. [8] The darkest skin type was not included.

Clinical data

There is limited clinical data and even less with long-term follow-up for flashlamps. [9] Arguably the best overview is Tse. [10] Several brief discussions suggest usefulness without detailing clinical data. [11, 12, 13, 14, 15]

The pilot study observed 60% reduction at 3 months [16] and 75% at 12 months. [17] Another study observed 80% reduction at 8 months. [18] One study with no follow-up observed 77% reduction immediately after a 6th treatment. [19]

Two articles reporting on overlapping patient groups reported 54% to 64% reduction at 6 months. A later study by the same authors observed 76% reduction immediately after a 4th treatment. [20] The study observed 41% of subjects had an average 83% reduction at 12 months or more. [21]

One clinical report found “satisfactory” results at 6 months in 2 transsexuals who received 13 and 41 treatments, respectively. [22] Another clinical report observed one patient had successful removal of transplanted scalp hair grafts with 1.5 year follow-up. [23]

One study had findings which aligned more closely with other reported light-based results, observing an average 33% reduction at 6 months after 2 treatments. [24]

Laser and flashlamp promoters sometimes suggest the devices are very different in terms of effectiveness or side effects, but this is not based on published comparative data.

References

  1. Verhagen AR. Light tests and pathogenetic wavelengths in chronic polymorphous light dermatosis. Dermatologica. 1966;133(4):302-12.
  2. L'Esperance FA Jr. Clinical comparison of xenon-arc and laser photocoagulation of retinal lesions. Archives of Ophthalmology. 1966 Jan;75(1):61-7.
  3. FDA Docket K950493. August 7 1995.
  4. Hellwig S, Schonermark M, Raulin C.[Treatment of vascular malformations and pigment disorders of the face and neck by pulsed dye laser, Photoderm VL and Q-switched ruby laser].Laryngorhinootologie. 1995 Oct;74(10):635-41. German.
  5. Goldman MP, Eckhouse S. Photothermal sclerosis of leg veins. ESC Medical Systems, LTD Photoderm VL Cooperative Study Group. Dermatologic Surgery. 1996 Apr;22(4):323-30.
  6. Schroeter CA, Neumann HA. An intense light source. The photoderm VL-flashlamp as a new treatment possibility for vascular skin lesions. Dermatologic Surgery. 1998 Jul;24(7):743-8.
  7. FDA Docket K963249. July 7, 1997.
  8. FDA Docket K991935. January 27, 2000.
  9. Please see hairfacts.com for a list of the flashlamp medical literature.
  10. Tse Y. Hair removal using a pulsed-intense light source. Dermatologic Clinics. 1999 Apr;17(2):373-85, ix.
  11. Fitzpatrick RF Goldman MP Sriprachyaanut S. Hair removal utilizing the ESC Epilight device. Lasers in Surgery and Medicine (supplement) 9 36:1997.
  12. Smith SR, Tse Y, Adsit SK et. al.Long-term results of hair photo-epilation. Lasers in Surgery and Medicine (supplement) 43:1998.
  13. Gold MH. Hair removal with an intense pulsed-light source. Lasers in Surgery and Medicine (supplement) 10 58:1998
  14. Weiss G, Cohen B. The efficacy of long-term epilation of unwanted hair by noncoherent filtered flashlamp. Lasers in Surgery and Medicine. 2000;26(4):345.
  15. Weir VM, Woo TY. Photo-assisted epilation: review and personal observations. Journal of Cutaneous Laser Therapy. 1999;1:135-143. PMID not available.
  16. Gold MH, Bell MW, Foster TD, Street S. Long-term epilation using the EpiLight broad band, intense pulsed light hair removal system. Dermatologic Surgery. 1997 Oct;23(10):909-13.
  17. Gold MH, Bell MW, Foster TD, Street S. One year follow-up using an intense pulsed light source for long-term hair removal. Journal of Cutaneous Laser Therapy. 1999;1:167-171. PMID not available.
  18. Trollius A, Troillus C. Hair removal with a second-generation broad spectrum intense pulsed light source: a long-term follow-up. Journal of Cutaneous Laser Therapy 1999;1:173-178. PMID not available.
  19. Schroeter CA,and others. Hair removal in 40 hirsute women with an intense laser-like light source. European Journal of Dermatology. 1999 Jul-Aug;9(5):374-9.
  20. Sadick NS, and others. Available Long-term photoepilation using a broad-spectrum intense pulsed light source. Archives of Dermatology. 2000 Nov;136(11):1336-40. PMID 11074695
  21. Sadick NS, Shea CR, Burchette JL Jr, Prieto VG. High-intensity flashlamp photoepilation: a clinical, histological, and mechanistic study in human skin. Archives of Dermatology. 1999 Jun;135(6):668-76.
  22. Raulin C, Werner S, Hartschuh W, Schonermark MP Effective treatment of hypertrichosis with pulsed light: a report of two cases. Annals of Plastic Surgery 1997 Aug;39(2):169-73 PMID 9262770
  23. Moreno-Arias GA, Navarra E, Vilalta A, Ferrando J. Corrective photoepilation for improper hairline placement after hair transplantation. Dermatologic Surgery. 2000 Aug;26(8):790-2; discussion 792.
  24. Weiss RA, Weiss MA, Marwaha S, Harrington AC. Hair removal with a non-coherent filtered flashlamp intense pulsed light source. Lasers in Surgery and Medicine. 1999;24(2):128-32.
 

Was this helpful?  Support this site!